EasyManuals Logo

Chromalox MicroTherm CMX Series User Manual

Chromalox MicroTherm CMX Series
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
User Instructions
TM
Figure 6.5
microTHERM™ Open and Closed-Loop Electrical Schematic
28
Heater
4.5 KW to 24 KW
Pump
Motor
Pump
Overload
Pump
Contactor
OL
1M-1
2L1
2T1
2L2
2L3
2T2
2T3
1C
1T11L1
1L2 1T2
1L3 1T3
3T3
3T1
Customer Supplied
Voltage
L1
L2
L3
GND
DI-1
5
1
1
120V
Fuse
1F
Pump
Overload
Indication
Overtemp
Indication
Cooling
Control
Heater
Control
Motor
Control
Pump
Low
Pressure
Indication
2
Stop
Start
1M-1
14
13
14
131211
5
6
Pressure
Switch
1PS
34
R
W
R
R
Low
Pressure
Pump
ON
X2
X1
1M
A1
A2
95
95
7
1C
9
54
53
8
Output #1
Output #2
10
Heater
Contactor
Cooling
Solenoid
Heater
Overtemp
Pump
Overload
Output #3
11
OL-1
98
97
12
1M-2-2
62
61
16
Type J
T/C
1ITC
1
2
3
4
5
6
7
8
9
19
20
21
22
23
24
25
26
27
10
11
12
13
14
15
16
17
18
Optional
Door Interlock
Output #4
+
-
1M-2-1
OL

Other manuals for Chromalox MicroTherm CMX Series