Questions and Answers

  • L
    Lindsey MartinAug 9, 2025
    What to do if the agitator will not rotate in my CIMLINE 105?
    • K
      Kathy DeanAug 9, 2025
      If the agitator isn't rotating, several factors could be at play. First, the sealant material might not be hot enough; allow more time for heating. If too many biscuits were added at once, continue heating and reverse agitation to break them free. Also, check the hydraulic oil level. Finally, a worn agitator motor could be the culprit, requiring replacement.
  • R
    Rhonda RossAug 23, 2025
    Why won't the burner ignite on my CIMLINE 105 Industrial Equipment?
    • M
      Matthew NewtonAug 23, 2025
      If the burner fails to ignite, several issues could be the cause. Start by checking the fuse and the primary control fuse. If those are fine, the burner relay might be inoperative, so check for 12 VDC at the relay. A clogged orifice can also prevent ignition, so clean it. Air in the fuel line could be another issue, so bleed the burner. Lastly, inoperative thermocouples can cause this problem, so replace them if necessary.