1-60
Cisco 7200 VXR Installation and Configuration Guide
OL-5013-09
Chapter 1 Cisco 7200 VXR Product Overview
Functional Overview
Ta b l e 1-34 NPE-G2 Processor-Monitored Temperature Thresholds
NPE-G2
1
1. With an I/O controller installed.
Low Warning High Warning Shutdown
NPE inlet 111•F (44•C)F (44•C) 138•F (59•C)F (59•C) 176
o
F (80
o
C)
NPE outlet 120•F (49•C)F (49•C) 147•F (64•C)F (64•C) 183•F (84•C)F (84•C)
I/O controller inlet 105•F (41•C)F (41•C) 132•F (56•C)F (56•C) 168•F (76•C)F (76•C)
I/O controller outlet 107•F (42•C)F (42•C) 134•F (57•C)F (57•C) 170•F (77•C)F (77•C)
CPU Die 194•F (90•C)F (90•C) 221•F (105•C)F (105•C) 230•F (110•C)F (110•C)
Ta b l e 1-35 NPE-G1 Processor-Monitored Temperature Thresholds
NPE-G1
1
1. With an I/O controller installed.
Low Warning High Warning Shutdown
NPE inlet 111•F (44•C)F (44•C) 138•F (59•C)F (59•C) 176•F (80•C)F (80•C)
NPE outlet 120•F (49•C)F (49•C) 147•F (64•C)F (64•C) 183•F (84•C)F (84•C)
I/O controller inlet 105•F (41•C)F (41•C) 132•F (56•C)F (56•C) 168•F (76•C)F (76•C)
I/O controller outlet 107•F (42•C)F (42•C) 134•F (57•C)F (57•C) 170•F (77•C)F (77•C)
Ta b l e 1-36 Typical Processor-Monitored Temperature Thresholds
Parameter High Warning High Critical Shutdown
NPE-175, NPE-225, NPE-300,
NPE-400, NSE-1
Chassis inlet 104•F (40•C)F (40•C) 122•F (50•C)F (50•C)
Chassis outlet 1 109•F (43•C)F (43•C) 127•F (53•C)F (53•C) 136•F (58•C)F (58•C)
Chassis outlet 2 109•F (43•C)F (43•C) 127•F (53•C)F (53•C)
Chassis outlet 3 122•F (50•C)F (50•C) 140•F (60•C)F (60•C) 149•F (65•C)F (65•C)
NPE-100 or NPE-200
Chassis inlet 104•F (40•C)F (40•C) 122•F (50•C)F (50•C)
Chassis outlet 1 109•F (43•C)F (43•C) 127•F (53•C)F (53•C) 136•F (58•C)F (58•C)
Chassis outlet 2 167•F (75•C)F (75•C) 167•F (75•C)F (75•C)
Chassis outlet 3 122•F (50•C)F (50•C) 140•F (60•C)F (60•C) 149•F (65•C)F (65•C)
NPE-150
Chassis inlet 104•F (40•C)F (40•C) 122•F (50•C)F (50•C)
Chassis outlet 1 109•F (43•C)F (43•C) 127•F (53•C)F (53•C) 136•F (58•C)F (58•C)
Chassis outlet 2 167•F (75•C)F (75•C) 167•F (75•C)F (75•C)
Chassis outlet 3 131•F (55•C)F (55•C) 149•F (65•C)F (65•C) 158•F (70•C)F (70•C)