1-64
Cisco 7200 VXR Installation and Configuration Guide
OL-5013-09
Chapter 1      Cisco 7200 VXR Product Overview
Functional Overview
Following is sample output of the show environment all command:
NPE300(boot)# show environment all
Power Supplies:
Power Supply 1 is empty.
Power Supply 2 is Zytek AC Power Supply. Unit is on.
Temperature readings:
chassis inlet    measured at 26C/78F 
chassis outlet 1 measured at 28C/82F 
chassis outlet 2 measured at 29C/84F 
chassis outlet 3 measured at 33C/91F 
Voltage readings:
+3.45 V       measured at +3.46 V 
+5.15 V       measured at +5.25 V 
+12.15 V      measured at +12.24 V 
-11.95 V      measured at -11.81 V 
Envm stats saved 138 time(s) since reload
Fan Failures
When the system power is on, all three fans should be operational. The system continues to operate if a 
fan fails; however, if the air temperature exceeds a defined threshold, the system controller displays 
warning messages on the console terminal, and if the temperature exceeds the shutdown threshold, the 
system controller shuts down the system.
If the system does shut down because the temperature exceeded the shutdown threshold, the system 
displays the following message on the console screen and in the environment display when the system 
restarts:
Queued messages:
%ENVM-1-SHUTDOWN: Environmental Monitor initiated shutdown
For complete descriptions and instructions for the environmental monitor commands, refer to the 
Configuration Fundamentals Configuration Guide and Configuration Fundamentals Command 
Reference publications, which are available on Cisco.com or the Documentation DVD.