1-63
Cisco 7200 VXR Installation and Configuration Guide
OL-5013-09
Chapter 1      Cisco 7200 VXR Product Overview
Functional Overview
Following is sample output of the show environment last command:
NPE300(boot)# show environment last
chassis inlet      previously measured at 26C/78F
  chassis outlet 1   previously measured at 28C/82F
  chassis outlet 2   previously measured at 29C/84F
  chassis outlet 3   previously measured at 33C/91F
  +3.45 V            previously measured at +3.46
  +5.15 V            previously measured at +5.23
  +12.15 V           previously measured at +12.24
  -11.95 V           previously measured at -11.81
  last shutdown reason - power supply shutdown
The show environment table command displays the temperature and voltage thresholds for each 
temperature sensor and for each monitored status level. These thresholds are related to those listed in 
Table 1-36 and Table 1-38. The display also lists the shutdown threshold for the system.
Following is sample output of the show environment  table command for a Cisco 7206VXR that has an 
installed NPE-300:
NPE300(boot)# show environment table
System shutdown for chassis inlet is 75C/167F
System shutdown for chassis outlet 1 is 58C/136F
System shutdown for chassis outlet 2 is 75C/167F
System shutdown for chassis outlet 3 is 65C/149F
Note Temperature ranges and values are subject to change.
The show environment all command displays an extended report that includes temperature readings and 
voltage readings. The show environment all command also displays a report showing which power 
supply slots are occupied and which are empty. 
Sample Point
chassis inlet 
chassis outlet 1 
chassis outlet 2 
chassis outlet 3 
+3.45 V  
+5.15 V 
+12.15 V  
-11.95 V 
LowCritical
 
 
 
 
+3.26 
+4.86  
+11.39 
-9.52
LowWarning
 
 
 
 
+3.34 
+4.99  
+11.67  
-10.73
HighWarning
40C/104F 
43C/109F 
75C/167F 
50C/122F 
+3.55 
+5.31 
+12.62  
-13.16 
HighCritical
50C/122F 
53C/127F 
75C/167F 
60C/140F 
+3.63  
+5.43  
+12.91 
-14.38