1-9
Cisco Aironet 1530 Series Outdoor Access Point Hardware Installation Guide
OL-30864-01
Chapter 1 Overview
Hardware Features
Warning
Do not work on the system or connect or disconnect cables during periods of lightning activity.
Statement 1001
Warning
Connect the unit only to DC power source that complies with the safety extra-low voltage (SELV)
requirements in IEC 60950 based safety standards.
Statement 1033
Warning
To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord.
Statement 1023
Caution Several forms of PoE are supported. See Table Table 2-7 for the PoE options and their corresponding
modes of operation.
Caution Do not place the power injector in an unprotected outdoor environment because water could get into the
power injector and cause a short circuit and possible fire.
Caution When the access point is installed outdoors or in a wet or damp location, the AC branch circuit that is
powering the access point should be provided with ground fault protection (GFCI), as required by Article
210 of the National Electrical Code (NEC).
Power injectors
The 1530 series access points support the following power injectors:
• AIR-PWRINJ1500-2= – 100-240 VAC input, indoor use only
• AIR-PWRINJ4= – 100-240 VAC input, indoor use only
Warning
To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord.
Statement 1023
Caution The power injector (AIR-PWRINJR4- and AIR-PWRINJ1500-2=) must be used in an indoor
environment only.
Caution When the access point is installed outdoors, or in a wet or damp location, the AC branch circuit that is
powering the access point should be provided with ground fault protection (GFCI), as required by Article
210 of the National Electrical Code (NEC).