EasyManuals Logo

Cisco ASR 1002 Replacing

Cisco ASR 1002
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #110 background imageLoading...
Page #110 background image
Figure 75: Cisco ASR 1001 Router AC Power Supply Standby Switch
Cisco ASR 1001 Router AC power supply Standby switch. This switch does not disconnect power from the power
source.
1
Step 2 Turn off the circuit breaker to the power supply.
Step 3 For easier installation, plug the power cable into the inlet on power supply slot 1 first.
Step 4 Insert the power supply cable into the power supply in slot 0 on the left.
Step 5 Ensure that the AC power cords are positioned, as shown in the following figure.
Figure 76: Correct Position of the Cisco ASR 1001 Router AC Power Supply Cables
AC power supply in PS13AC power supply in PS01
Removing and Replacing FRUs from the Cisco ASR 1000 Series Routers
110
Removing and Replacing FRUs from the Cisco ASR 1000 Series Routers
Installing the AC Power Supply into Cisco ASR 1001 Router

Other manuals for Cisco ASR 1002

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR 1002 and is the answer not in the manual?

Cisco ASR 1002 Specifications

General IconGeneral
Ethernet LANYes
Cabling technology10/100/1000Base-T(X)
Networking standardsIEEE 802.3
Ethernet LAN data rates10, 100, 1000 Mbit/s
Ethernet interface typeGigabit Ethernet
DHCP client-
Supported network protocolsBGP, GRE, OSPF, DVMRP, EIGRP, IS-IS, IGMPv3, PIM-SM, PIM-SSM
Ethernet LAN (RJ-45) ports4
Security algorithmsSSH
VPN tunnels quantity8000
SafetyUL60950-1 CSA, C22.2 No. 60950-1-03, EN 60950-1, IEC 60950-1, AS/NZS 60950.1
CertificationFCC 47CFR15 Class A AS/NZS CISPR 22 CISPR 22 Class A EN55022 Class A ICES-003 Class A VCCI Class A CNS-13438 Class A EN61000-3-2 EN61000-3-3
Internal memory4096 MB
AC input voltage85 - 264 V
Power source typeAC
AC input frequency50 - 60 Hz
Power consumption (typical)560 W
Operating altitude0 - 3048 m
Storage temperature (T-T)0 - 50 °C
Operating temperature (T-T)0 - 40 °C
Storage relative humidity (H-H)5 - 95 %
Operating relative humidity (H-H)5 - 90 %
Product colorGray
Rack capacity2U
Weight and Dimensions IconWeight and Dimensions
Depth461 mm
Width437.4 mm
Height89 mm
Weight- g