34
Cisco IOS XE 3S Release Notes for the Cisco ASR 903 Router
OL-26630-12
Chapter
Caveats in Cisco IOS XE 3.8S Releases
Conditions: Upgrade to the new firmware rev. and a subsequent switchover. Occurs when you
upgrade the router to a new firmware version and issue an RSP switchover.
Workaround: Reloading the RSP can resolve the issue.
CSCud60410
Symptom: The router drops EFP traffic.
Conditions: Occurs when you add a new EFP to an existing bridge domain interface (BDI) while
running L3 multicast.
Workaround: Issue a shutdown/no shutdown on the Ethernet interface and issue the clear ip
mroute command.
CSCud61931
Symptom: As OC-3 interface module controller does not become active using loopback local.
Conditions: Occurs with the A900-IMA4OS interface module when there is no SFP inserted in the
port.
Workaround: Insert an SFP in the appropriate port.
CSCud64347
Symptom: The router creates a data loop when using a REP VLAN load balancing configuration.
Conditions: Occurs with a REP VLAN load balancing configuration when a bridge-domain is
bound to a VPLS VC.
Workaround: None; remove the VLAN load balancing configuration.
CSCud64923
Symptom: OSPF connections flap.
Conditions: Occurs when you configure OSPF between an EVC bridge domain interface (BDI) and
a trunk EFP bridge domain interface (BDI) using a port-channel trunk.
Workaround: There is no workaround.
CSCud65779
Symptom: The router does not update the Rx value for C2, J1, and S1S0 bytes.
Conditions: Occurs when you configure overhead bytes on OC-3 connections.
Workaround: There is no workaround.
CSCud65935
Symptom: End to end ATM ping does not work.
Conditions: Occurs when you configure a different set of VPI/VCI on either end of an ATM layer
2 circuit.
Workaround: Configure the same VPI/VCI values on both sides of the connection.
CSCud71546
Symptom: The ten Gigabit Ethernet interface drops traffic for 7 seconds following a stateful
switchover (SSO).
Conditions: Occurs when the configuration contains static routes to the destination.
Workaround: There is no workaround.
CSCud76209
Symptom: The OC-3 interface module goes into an out of service state.

Table of Contents

Other manuals for Cisco ASR 900 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR 900 Series and is the answer not in the manual?

Cisco ASR 900 Series Specifications

General IconGeneral
BrandCisco
ModelASR 900 Series
CategoryNetwork Router
LanguageEnglish

Related product manuals