EasyManua.ls Logo

Cisco Catalyst C9300-48T

Cisco Catalyst C9300-48T
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Power Requirements
PWR-C1-1100WAC and PWR-C1-1100WAC-P:
12–6 A
PWR-C1-715WAC: 10–5 A
PWR-C1-350WAC: 4–2 A
Input current
PWR-C1-1100WAC and PWR-C1-1100WAC-P:
–56 V@19.64 A
PWR-C1-715WAC: –56 V@12.8 A
PWR-C1-350WAC: –56 V@6.25 A
Output ratings
PWR-C1-1100WAC and PWR-C1-1100WAC-P:
4263 BTUs per hour, 1250 W
PWR-C1-715WAC: 2742 BTUs per hour, 804
W
PWR-C1-350WAC: 1357 BTUs per hour, 398
W
Total input BTU
8
PWR-C1-1100WAC and PWR-C1-1100WAC-P:
3751 BTUs per hour, 1100 W
PWR-C1-715WAC: 2438 BTUs per hour, 715
W
PWR-C1-350WAC: 1194 BTUs per hour, 350
W
Total output BTU
9
8
The total input and total output BTU ratings refer to input power to the power supply and output power
to the switch. The BTU ratings are based on 100 VAC for the 350-W and 715-W power supplies and
115 VAC for the 1100-W power supply.
9
The total input and total output BTU ratings refer to input power to the power supply and output power
to the switch. The BTU ratings are based on 100 VAC for the 350-W and 715-W power supplies and
115 VAC for the 1100-W power supply.
Table 39: Fan Module Environmental and Physical Specifications
Environmental Ranges
23 to 176°F (–5 to 80°C)
Operating temperature
–40 to 185°F (–40 to 85°C) up to 15,000 ft (4500 m)Storage temperature
5 to 95% (noncondensing)Relative humidity
Up to 13,000 ft (4000 m)Altitude
Physical Specification
Cisco Catalyst 9300 Series Switches Hardware Installation Guide
96
Technical Specifications
Technical Specifications

Table of Contents