Loading...
930-W DC power supply support 1+1 redundancy requires both of the following
conditions:
Ambient temperature of 104°F (40) or less and
Use of 3.5 W QSFP+ transceivers or passive QSFP cables
With higher temperatures or other optics, the switch requires both power supplies
for operations without power redundancy.
Note
Both power supplies are the same type. Do not mix AC, DC, or HVAC/HVDC
power supplies.
Note
All fan modules and power supplies must use the same airflow direction. If you
are using the 1200-W HVAC/HVDC power supplies, those power supplies
automatically use the same airflow direction as used by the fan modules.
Note
Deployment Scheme for SFP-10G-T-X Transceivers
The following figure shows the maximum configuration density of SFP-10G-T-X SFP+ transceivers for this
switch.
The following figure shows the switch features on the port side of the chassis.