Lane Link LEDs
The Lane Link LEDs indicate which of the break out lanes are being checked. If none of the Lane Link LEDs
is lit, all four lanes are being checked.
DescriptionLED Lit
Checking lane 1.1
Checking lane 2.2
Checking lane 3.3
Checking lane 4.4
Checking all four lanesNone
Fan Module LEDs
The fan module LED is located below the air holes on the front of the module.
StatusColorLED
The fan module is operational.GreenSTS
The fan module is not operational (fan is probably not functional).Red
Fan module is not receiving power.Off
Power Supply LEDs
The power supply LEDs are located on the left front portion of the power supply. Combinations of states
indicated by the Okay ( ) and Fault ( ) LEDs indicate the status for the module as shown in the following
table.
Status
LED
LED
Power supply is on and outputting power to the switch.OffGreen
Power supply is connected to a power source but not outputting power to the
switch—power supply might not be installed in the chassis.
OffFlashing
green
Power supply is not receiving power or is in shut mode.OffOff