4-26
Cisco ONS 15501 User Guide
78-14134-01, Release 1.0
Chapter 4 Command Reference
outsigpwr
outsigpwr
To display the calculated output signal power, use the outsigpwr command.
outsigpwr
Syntax Description
Defaults None
Command Types Does not change configuration
Command Modes User password protected
Command History
Usage Guidelines The value for calculated output signal power is displayed in dBm.
Examples The following example shows how to display the calculated output signal power.
edfa > outsigpwr
-28.53 (dBm)
Related Commands
This command has no other arguments or keywords.
Release Modification
EDFA 1.0 This command was introduced.
Command Description
outsigpwrmean Displays the output signal alarm mean level.
outsigpwrtrig Displays the output signal alarm trigger level.
resetmeantrig Resets the signal gain and alarm mean level, gain alarm trigger level, optical
input alarm mean level, optical input alarm trigger level, output signal alarm
mean level, output signal alarm trigger level, internal case temperature
alarm mean level, and internal case temperature alarm trigger level to the
manufacturers default settings.
setoutsigpwrmean Sets the output signal alarm mean level.
setoutsigpwrtrig Sets the output signal alarm trigger level.