4-33
Cisco ONS 15501 User Guide
78-14134-01, Release 1.0
Chapter 4 Command Reference
resetmeantrig
resetmeantrig
To reset the alarm mean and trigger levels for signal gain, optical input power, output signal power, and
internal case temperature to the manufacturers default settings, use the resetmeantrig command.
resetmeantrig
Syntax Description
Defaults None
Command Types Changes configuration
Command Modes Master password protected
Command History
Usage Guidelines The manufacturers default setting for signal gain and alarm mean level is 17.50 dB.
The manufacturers default setting for gain alarm trigger level is 1.00 dB.
The manufacturers default setting for optical input alarm mean level is -29.00 dBm.
The manufacturers default setting for optical input alarm trigger level is 1.00 dBm.
The manufacturers default setting for output signal alarm mean level is 2.00 dBm.
The manufacturers default setting for output signal alarm trigger level is 20.00 dBm.
The manufacturers default setting for internal case temperature alarm mean level is 30°C.
The manufacturers default setting for internal case temperature alarm trigger level is 30°C.
Related Commands
This command has no other arguments or keywords.
Release Modification
EDFA 1.0 This command was introduced.
Command Description
gainmean Displays the configured signal gain and alarm mean level.
gaintrig Displays the gain alarm trigger level.
inpwrmean Displays the optical input alarm mean level.
inpwrtrig Displays the optical input alarm trigger level.
outsigpwrmean Displays the output signal alarm mean level.
outsigpwrtrig Displays the output signal alarm trigger level.
setgainmean Sets the signal gain and alarm mean level.
setgaintrig Sets the gain alarm trigger level.

Table of Contents