A-2
Cisco ONS 15501 User Guide
78-14134-01, Release 1.0
Appendix A Technical Specifications
Cisco ONS 15501 Mechanical Specifications
Cisco ONS 15501 Mechanical Specifications
Table A-2 lists the mechanical specifications of the Cisco ONS 15501.
Cisco ONS 15501 DC Input Power Requirements
Table A-3 lists the DC input power requirements of the Cisco ONS 15501.
Table A-2 Cisco ONS 15501 Mechanical Specifications
Description Specification
Dimensions (H x W x D) 1.7 in. x 19.0 in. x 10.1 in.
(44.45 mm x 482.6 mm x 259 mm)
Weight 6.8 lbs
Ambient operating temperature 0 to 50°C (32 to 122°F)
Storage temperature -40 to 85°C (-40 to 185°F)
Humidity operation Up to 95 percent, noncondensing
Humidity storage Up to 95 percent, noncondensing
Connector type SC/UPC
Table A-3 DC Input Power Supply Specifications
Description Specification
Power consumption 15W maximum; 8W typical
Input power cable 8 AWG wire
Power source voltage range -40.5 VDC to -57.0 VDC