Configure the Rack Server
To configure and check connectivity for a rach server, follow the steps in the Configure Fabric Interconnect
A for UCS Mini, on page 75 section through the "Event Logs" subsection.
Reset Fabric Interconnects
To reset the fabric interconnects, follow theses steps:
Before you begin
After completion of examining the text log files, save the files in the designated location.
Procedure
Step 1 At the Fabric Interconnect B console, enter the following command:
Example:
Fabric-B# connect local
Fabric-B (local-mgt)# erase config
Step 2 At the warning prompt, enter Yes.
Step 3 Do not disconnect the fabric interconnect until it starts to reboot.
Step 4 After the fabric interconnect power cycles and initializes, disconnect the power cords.
Step 5 Repeat the preceding steps for Fabric Interconnect A.
Step 6 When the configurations on both fabric interconnects have been erased, reconnect the power cords.
Step 7 Verify that both fabric interconnects reboot and prompt you to Enter the configuration method.
Cleanup
To clean up after running diagnostics, follow these steps:
Procedure
Step 1 Power off all applicable PDUs in the rack.
Step 2 Disconnect the Digi Console and the Mgmt0 cables.
Cisco R42612 Rack and RP-Series Metered Input PDU Installation Guide
80
Integrating UCS Components in the Dynamic Rack
Configure the Rack Server