Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
18
CONFIGURING the SERVER
Approved Configurations
(1) 1-CPU configuration without memory mirroring:
Select from 1 to 8 DIMMs. Refer to Memory Population Rules, page 59, for more detailed
information.
(2) 1-CPU configuration with memory mirroring:
Select 2, 4, 6, or 8 identical DIMMs. The DIMMs will be placed by the factory as shown in the
following table.
Select the memory mirroring option (N01-MMIRROR) as shown in Ta bl e 4 on page 17.
(3) 2-CPU configuration without memory mirroring:
Select from 1 to 8 DIMMs per CPU. Refer to Memory Population Rules, page 59, for more
detailed information.
To t al
Number
of
DIMMs
CPU 1 DIMM Placement in Channels
(for
identical DIMMs)
Blue Slots Black Slots
2 (A1, B1)
4 (A1,B1); (C1,D1)
6
1
Notes . . .
1. Not recommended (for performance reasons)
(A1,B1, C1) (A2, B2, C2)
8 (A1,B1); (C1,D1) (A2,B2); (C2,D2)