Environmental Specifications
Environmental Ranges
23 to 113°F (5 to 45°C) up to 5,000 ft (1500 m)
23 to 104°F (5 to 40°C) up to 10,000 ft (3000 m)
Operating temperature
3
-13º to 158ºF (-25º to 70ºC) up to 15,000 ft (4500 m)Storage temperature
5% to 90% (noncondensing)Operating relative humidity
5% to 95% (noncondensing)Storage relative humidity
Up to 15,000 ft (4500 m)Storage altitude
3
Minimum ambient temperature for cold start is 32°F (0°C)
When using these switches with GLC-T SFP module, the thermal limitations are as follows:
Up to 5000 feet, the operating temperature should not exceed 40°C.
Up to 10000 feet, the operating temperature should not exceed 35°C.
Power Requirements
Power Requirements
110 to 220 VAC (autoranging)
0.27 to 0.41 A, 50 to 60 Hz (Cisco Catalyst 2960L-24TS-LL)
1.14 to 2.25 A, 50 to 60 Hz (Cisco Catalyst 2960L-24PS-LL)
0.42 to 0.68 A, 50 to 60 Hz (Cisco Catalyst 2960L-48TS-LL)
2.17 to 3.83 A, 50 to 60 Hz (Cisco Catalyst 2960L-48PS-LL)
AC input voltage
0.06 KVA (Cisco Catalyst 2960L-24TS-LL)
0.24 KVA (Cisco Catalyst 2960L-24PS-LL)
0.09 KVA (Cisco Catalyst 2960L-48TS-LL)
0.48 KVA (Cisco Catalyst 2960L-48PS-LL)
Power rating