Citrix ADC MPX
Always disconnect the appliance from power before removing or installing any component, un-
less the component is hot-swappable. When disconnecting power, first shut down the appli-
ance, and then unplug the power cords of all the power supply units connected to the appliance.
As long as the power cord is plugged in, line voltages can be present in the power supply, even
when the power switch is OFF.
Do not use mats designed to decrease static electrical discharge as protection from electrical
shock. Instead, use rubber mats that have been designed as electrical insulators.
Ensure that the power source can handle the appliance’s maximum power consumption rating
with no danger of an overload. Always unplug any appliance before performing repairs or up-
grades.
Do not overload the wiring in your server cabinet or on your server room rack.
During thunderstorms, or anticipated thunderstorms, avoid performing any hardware repairs
or upgrades until the danger of lightning has passed.
When you dispose of an old appliance or any components, follow any local and national laws
on the disposal of electronic waste.
To prevent possible explosions, replace expired batteries with the same model or a
manufacturer-recommended substitute and follow the manufacturer’s instructions for
battery replacement and disposal.
This product is also designed for an IT power distribution system with phase-to-phase voltage
230 V.
Never remove a power supply cover or any sealed part that has the following label:
Appliance precautions:
Determine the placement of each component in the rack before you install the rails.
Install the heaviest appliance first, at the bottom of the rack, and then work upward. Distribute
the load on the rack evenly. An unbalanced rack is hazardous.
Allow the power supply units and hard drives to cool before touching them.
Install the equipment near an electrical outlet for easy access.
Mount equipment in a rack with suicient airflow for safe operation.
For a closed or multiple-unit rack assembly, the ambient operating temperature of the rack envi-
ronment might be greater than the ambient temperature of the room. Therefore, consider the
lowest and highest operating temperatures of the equipment when making a decision about
where to install the appliance in the rack.
© 19992022 Citrix Systems, Inc. All rights reserved. 130

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Citrix ADC MPX 5550 and is the answer not in the manual?

Citrix ADC MPX 5550 Specifications

General IconGeneral
BrandCitrix
ModelADC MPX 5550
CategoryNetwork Hardware
LanguageEnglish

Related product manuals