Citrix ADC MPX
4. Select the severity level of the events for which to generate alerts.
5. Set Destination IP to the IP address at which you installed the IPMI View utility.
6. Optionally, to receive alerts by email, specify an email address. To avoid receiving email for
routine alerts, specify a severity higher than Informational.
7. Click Save.
8. The LOM starts sending alerts to the IPMI View utility within in a minute or two. Aer the IPMI
View utility starts receiving alerts from the LOM, reconfigure the destination IP address to point
to your SNMP Network Management Soware, such as HP OpenView.
Set up SNMP alerts on the LOM by using the Citrix ADC shell
To customize your filter and policy settings, see the IPMI Specification 2.0 rev. 1.1 documentation.
The latest IPMI specifications are available from the IPMI section of the Intel website:
http://www.intel.com/content/www/us/en/servers/ipmi/ipmi-specifications.html
Usually, customization in the SNMP Network Management Soware is the preferred method, because
it can be done one time at a central location. Therefore, the following settings send all events for all
sensors totheSNMP networkmanagement soware. These events are low traic events and therefore
do not result in any significant network usage.
Set up SNMP filters
The following commands set up SNMP to allow all events:
ipmitool raw 4 0x12 0x6 0x10 0x80 1 1 0 0xff 0xff 0xff 0xff 0xff 0xff 0xff
0 0xff 0 0 0xff 0 0 0xff 0
Set up a policy list
The following command creates a policy list for all sensors and events:
ipmitool raw 4 0x12 9 0x10 0x18 0x11 0x81
Set up the destination address for SNMP events
The following command sets up a destination IP address for an SNMP event:
ipmitool lan alert set 1 1 ipaddr <x.x.x.x>
Where, <x.x.x.x> is the IP address to which the SNMP event is sent.
© 1999‒2022 Citrix Systems, Inc. All rights reserved. 165