Citrix ADC MPX
Health
attributes/-
Platform
SNMP
Alarm
Support
MPX
17500/19500/21500MPX 115xx
MPX
17550/19550/20550/21550MPX8005/8015/8200/8400/8600/8800
MPX
5550/5650/5750
-12.0 V
Supply
(Volts)
No - NA - - NA - - NA - (-10.80)–(-
13.20)
(-10.80)–(-
13.20)
Battery
(Volts)
No 2.85–3.37 3–3.5 2.8–3.5 > 2.5 > 2.5
Intel CPU
Vtt Power
(Volts)
No 1–1.2 1–1.2 1–1.2 - NA - - NA -
5 V Standby
(Volts)
No 4.88–5.2 4.8–5.25 4.9–5.3 - NA - - NA -
Voltage
Sensor2
(Volts)
No 1.4–5.2 1.4–6.24 1.4–5.2 3.14–3.47 3.14–3.47
CPU Fan 0
Speed
(RPM)
Yes 3000–
16000
3000–
16000
3000–
16000
> 5500 > 5500
CPU Fan 1
Speed
(RPM)
Yes 3000–
16000
3000–
16000
3000–
16000
> 5500 > 5500
System Fan
Speed
(RPM)
Yes 900–15000 900–15000 900–15000 > 5500 > 5500
System Fan
1 Speed
(RPM)
No 900–15000 900–15000 900–16000 > 5500 > 5500
System Fan
2 Speed
(RPM)
No 900–15000 900–15000 900–16000 > 5500 > 5500
CPU 0 Tem-
perature
Yes 24–90
(Celsius),
75.2–194
(Fahren-
heit)
24–90
(Celsius),
75.2–194
(Fahren-
heit)
24–90
(Celsius),
75.2–194
(Fahren-
heit)
< 85
(Celsius), <
185 (Fahren-
heit)
< 85
(Celsius), <
185 (Fahren-
heit)
© 19992022 Citrix Systems, Inc. All rights reserved. 197

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Citrix ADC MPX 5550 and is the answer not in the manual?

Citrix ADC MPX 5550 Specifications

General IconGeneral
BrandCitrix
ModelADC MPX 5550
CategoryNetwork Hardware
LanguageEnglish

Related product manuals