193
SPECIAL FEATURES : AIR CONDITIONING SYSTEM (R 134.a)
Changing the filtering/drying cartridge
Refitting
Remove the new cartridge from its packaging.
Do not expose the cartridge, the filter and seals to pollutants.
Lightly oil the seals (compressor oil).
Remove tool [5] from the reservoir (4).
Insert the new cartridge (5) into the reservoir (4).
Refit the safety circlip (3), using tool [6].
Make sure that the circlip (3) is correctly positioned in its location.
WARNING : Not more than 5 minutes should elapse between the removal
of the cartridge (5) from its packaging and its being fitted.
Refit:
- The plastic cap (2), using tool [5]
- Tighten to 1,2 ± 0,1 m.daN.
- The condenser (reclip, pushing at «a» and «b»).
- The pin (1).
- The front bumper (see corresponding operation).
Proceed to:
- Recharge the circuit (see corresponding operation).
- Check the operation of the air conditioning (see corresponding operation).
C4AP1BYC C4AP1BWC