EasyManua.ls Logo

CITROEN C8 2002 - 4 HP 20 Gearbox: Fluid Service Procedures; Preliminary Conditions for Fluid Service; Tools for Gearbox Fluid Service; Gearbox Fluid Service Checks

CITROEN C8 2002
133 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
93
DRAIN / REFILL /TOP-UP : 4 HP 20 GEARBOX
CLUTCH
GEARBOX
DRIVESHAFTS
Engine : XFW
Preliminary conditions:
Checks there are no faults , using the diagnostic tool.
Place the vehicle on a lift, keep vehicle horizontal.
Gear lever in position «P», without applying the handbrake.
Heavy electrical consumers disconnected.
Connect the diagnostic tool.
Select the parameter measures function.
Make starting this operation, make sure that the oil temperature is well
below 55°C; if it is not, allow the oil to cool.
Press the brake pedal.
Start the engine and allow it to run at idling speed, engage all the gears
using the gear selector. Return to «P».
Tools.
[1] Filling kit : (-).0341
[1a] Filling cylinder : (-).0341-A
[1b] 4 HP 20 adaptor without gauge : (-).0341-B
NOTE :
- The 4 HP 20 automatic gearbox is lubricated for life.
- Check the level every 20 000 miles.
Checks
IMPERATIVE : Use only ESSO LT 71141.

Table of Contents