EasyManua.ls Logo

CKD ABSODEX AX9000XS-U2 - Page 34

Default Icon
43 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4. Network Operation Mode
[SMF-2008-A]
– 4-3 –
Table 4.1. Point table data list (2/2)
Table
number
Correspon
ding PRM
number
Description Set range Initial value
0 203
A code/P code
-4,194,304~
4,194,304
0
Set the set values (values equivalent to A code and P code of NC program)
such as the angle depending on the descriptions of the instruction and
movement unit within the following range.
In case of angle
:-360,000~360,000
x 1,000 [deg.]
In case of pulse
:-4,194,304~4,194,304
[Pulse]
In case of number of
indexes and segments
:1~255
[Number of indexes
and segments]
In case of gain
magnification
: 0, 50 to 200
[%]
204
F code
*1
10~240,000
2,000
Set the set values (values equivalent to F code of NC program) such as the
rotation speed depending on the descriptions of the instruction and
movement speed unit within the following range.
In case of rotation speed :110~240,000 x 1,000 [rpm]
In case of time :10~100,000 x 1,000 [sec]
n
(1~63)
200
+ 5 x n
Instruction
0~11
0
Refer to the explanation of the instruction of table 0.
201
+ 5 x n
Movement unit
0~3
0
Refer to the explanation of the movement unit of table 0.
202
+ 5 x n
Movement speed unit 0~2 0
Refer to the explanation of the movement speed unit of table 0.
203
+ 5 x n
A code/P code
-4,194,304
~4,194,304
0
Refer to the explanation of the A code/P code of table 0.
204
+ 5 x n
F code 10~240,000 2,000
Refer to the explanation of the F code of table 0.
Note *1: In the NC program, the initial value of the movement speed unit is the movement
time [sec]. In the point table, the initial value is the rotation speed [rpm].