4. Network Operation Mode
[SMF-2008-A]
ā 4-3 ā
Table 4.1. Point table data list (2/2)
Table
number
Correspon
ding PRM
Description Set range Initial value
0 203
A code/P code
-4,194,304~
0
Set the set values (values equivalent to A code and P code of NC program)
such as the angle depending on the descriptions of the instruction and
movement unit within the following range.
In case of number of
indexes and segments
[Number of indexes
and segments]
magnification
204
*1
Set the set values (values equivalent to F code of NC program) such as the
rotation speed depending on the descriptions of the instruction and
movement speed unit within the following range.
In case of rotation speed :110~240,000 x 1,000 [rpm]
In case of time :10~100,000 x 1,000 [sec]
n
(1~63)
200
+ 5 x n
Refer to the explanation of the instruction of table 0.
201
+ 5 x n
Refer to the explanation of the movement unit of table 0.
202
+ 5 x n
Movement speed unit 0~2 0
Refer to the explanation of the movement speed unit of table 0.
203
+ 5 x n
A code/P code
-4,194,304
0
Refer to the explanation of the A code/P code of table 0.
204
+ 5 x n
F code 10~240,000 2,000
Refer to the explanation of the F code of table 0.
Note *1: In the NC program, the initial value of the movement speed unit is the movement
time [sec]. In the point table, the initial value is the rotation speed [rpm].