91 2023-09-22 SM-A63469-A/2
<To Use the Positioning Completion Output Time (PRM13=2: Shipment Setting)>
You can use PRM47 to enter the positioning completion time between “0 and 1,000 msec.”
If PRM47=0, no positioning completion output is issued.
If PRM47 is changed to “0,” no positioning completion output is issued and the answer input
becomes unnecessary even if PRM13 (answer input after completion of positioning and
home return) is “1: Required.”

Table of Contents