g)Donotusethefollowingaircircuitswhenblowingairfromthedetectionnozzle.
・Circuitwithcheckvalve
   Thecheckvalveactsasexhaustresistance,andlimitstheadjustablerange.
・Circuitwithshuttlevalveand2-wayvalve
   ResidualpressureintheOUTsideofthe2-wayvalvepreventscorrectdetection.
   Evenifa3-wayvalveisused,theshuttlevalvemayvibrateexcessively.
a)Theentryofcompressoroilandtarrysubstancesmayobstructtheflowofairand
resultinproblems.Regularlyinspectthecompressoranddischargedrainage.
b)Keeptheairflowconstantsocoolantandoildonotflowbackfromthedetection
nozzle,oruseasolenoidvalvewithneedleandletinasmallamountofairfromthe
bypassasshownintherecommendedcircuit.
CAUTION
WARNING
PROPER
OPERATION
−11− [SM-P00143-A]