TROUBLESHOOTING
Settingisnotcorrect Performsettingcorrectly.
Airleakage
Connectpipingcorrectlyand
eliminateanyairleakage.
TheindicatorLEDoperates
correctly.
OutputdoesnotturnON
Incorrectwiring Connectwirescorrectly.
Selectedproductisnotcorrect
Checkiftheoutputspecification
(NPN/PNP)iscorrect.
Troublesymptom MajorCauses Remedies
OutputdoesnotturnON
Supplypressureerror
OutputstaysON
(DoesnotturnOFF)
Settingisnotcorrect Performsettingcorrectly.
Cloggedpiping
Applypressurelowerthanthe
withstandpressuretoeliminate
thecauseofcloggingofpiping.
Supplyratedpressure.
(50kPato200kPa)
TROUBLE
SHOOTING
−29− [SM-P00143-A]