CI Man u al Page 13
RETURN TO NORMAL MODE
Step 16S – Set Low Salt Warning using or . If value is set to:
• oFF, no low salt level warning will appear for the user; or
• a speci c value, “FILL SALT” will ash on the display when the
calculated remaining kg of salt falls below that level. Allowable values
range from 5 to 400 Kg in 5 Kg increments.
Press NEXT to exit OEM Softener System Setup. Press REGEN to return
to previous step.
Step 12S – Set Relay 1 Deactivate Time using or .
• If Set Time on is selected in Step 10S the relay will deactivate after the time set has expired.
Ranges from 1 second to 200 minutes.
• If Set L on or Set L Softening Regen on is selected in Step 10S the relay will deactivate after the
time set has expired or after the meter stops registering ow, whichever comes rst. Ranges from 1
second to 20 minutes.
Press NEXT to go to Step 13S. Press REGEN to return to previous step.
STEP 12S
STEP 13S
Step 13S – Set Relay 2 operation using or . The choices are:
• Set Time on: Relay activates after a set time at the beginning of a
regeneration cycle and then deactivates after a set period of time. The
start of regeneration is de ned as the rst backwash cycle or Dn brine
cycle, whichever comes rst.
• Set L Softening on: Relay activates after a set volume has been used
while in service, then deactivates after the meter stops registering ow and the set time period has
expired.
• Set L Softening Regen on: Relay activates after a set volume has been used while in service or
during regeneration, then deactivates after the meter stops registering ow and the set time period
has expired.
• Error: Relay closes whenever the control enters the Error Mode, and immediately deactivates when
the error mode is exited.
• Set Off: If set to Off, Steps 14S and 15S will not be shown.
Press NEXT to go to Step 14S. Press REGEN to return to previous step.
Step 14S – Set Relay 2 Actuation Time or Liters using or . The choices are:
• Relay Actuation Time: After the start of a regeneration the amount of time that should pass prior to
activating the relay. The start of regeneration is de ned as the rst backwash cycle or Dn brine/Up
brine cycle, whichever comes rst. Ranges from 1 second to 200 minutes.
• Relay Actuation Liters: Relay activates after a set number of Liters has passed through the meter
when the valve is in the Service mode. Ranges from 1 to 200 Liters.
Press NEXT to go to Step 15S. Press REGEN to return to previous step.
STEP 14S
Step 15S – Set Relay 2 Deactivate Time using or .
• If Set Time on is selected in Step 13S the relay will deactivate after the time set has expired.
Ranges from 1 second to 200 minutes.
• If Set L on or Set L Softening Regen on is selected in Step 13S the relay will deactivate after the
time set has expired or after the meter stops registering ow, whichever comes rst. Ranges from 1
second to 20 minutes.
Press NEXT to go to Step 16S. Press REGEN to return to previous step.
STEP 15S
STEP 16S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Clack V15CIDTG-05 and is the answer not in the manual?

Clack V15CIDTG-05 Specifications

General IconGeneral
BrandClack
ModelV15CIDTG-05
CategoryControl Unit
LanguageEnglish

Related product manuals