11.0 Technical Data
11.1 Process and Operating Data
11.1.1 WS1 20-80 L
PARAMETER UNITS 25L 30L 40L 50L 60L 80L
MAX.SERVICE
FLOW
M3/hr 1 1.2 1.6 2 2.4 3.2
SYSTEM CAPACITY Kg
CaCO3
1.25 1.5 2 2.5 3 4
CAPACITY @
300PPM
M3 4.1 5 6.6 8.3 10 13.3
SALT USED PER
REGEN
Kg 3.5 4.2 5.6 7 8.4 11.2
REGENERATION
TIME
MIN 48 68 72 72 72 72
SALT STORAGE
CAPACITY
Kg 60 60 100 130 130 130
MAX OPERATING
TEMP
O
C 50 50 50 50 50 50
MAX FLOW TO
DRAIN
LIT/MIN 5.7 9 9 9 15.14 15.14
IMPORTANT NOTES
Much of the data quoted in the above table is affected by the inlet pressure,
and so should be regarded as nominal only.
Total flow to drain will be similarly affected and is therefore not quoted, but
will be about 6 times the resin volume.