EasyManuals Logo

Clack WS2 series User Manual

Default Icon
27 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
WS1, 1.5 & 2 Series Watersoftener
Installation Operation Maintenance Manual
SIMPWS1 REV3 13/07/11 PAGE 17 OF27
11.0 Technical Data
11.1 Process and Operating Data
11.1.1 WS1 20-80 L
PARAMETER UNITS 25L 30L 40L 50L 60L 80L
MAX.SERVICE
FLOW
M3/hr 1 1.2 1.6 2 2.4 3.2
SYSTEM CAPACITY Kg
CaCO3
1.25 1.5 2 2.5 3 4
CAPACITY @
300PPM
M3 4.1 5 6.6 8.3 10 13.3
SALT USED PER
REGEN
Kg 3.5 4.2 5.6 7 8.4 11.2
REGENERATION
TIME
MIN 48 68 72 72 72 72
SALT STORAGE
CAPACITY
Kg 60 60 100 130 130 130
MAX OPERATING
TEMP
O
C 50 50 50 50 50 50
MAX FLOW TO
DRAIN
LIT/MIN 5.7 9 9 9 15.14 15.14
IMPORTANT NOTES
Much of the data quoted in the above table is affected by the inlet pressure,
and so should be regarded as nominal only.
Total flow to drain will be similarly affected and is therefore not quoted, but
will be about 6 times the resin volume.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Clack WS2 series and is the answer not in the manual?

Clack WS2 series Specifications

General IconGeneral
Model SeriesWS2
Pressure Rating125 PSI
MeteredYes
Time ClockYes
Regeneration TypeDownflow or Upflow
Cycle AdjustmentYes
Materials of ConstructionNoryl
TypeWater Softener
Flow Rate12 GPM
Control ValveFleck 5600
Valve Size1"

Related product manuals