EasyManua.ls Logo

Clack WS2 series - Factory Programming Procedures

Default Icon
27 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WS1, 1.5 & 2 Series Watersoftener
Installation Operation Maintenance Manual
SIMPWS1 REV3 13/07/11 PAGE 10 OF27
NEXT
NEXT
NEXT
NEXT
NEXT
NEXT
regeneration has been entered as 2 AM, this can be changed if
necessary.
6.3 Factory Programming
Regeneration Programming
(All programming below is Factory set)
To alter settings – Press “↑” and “ keys To back up at any stage Press
“REGEN” To save any changes Press SET CLOCK”
Press and hold together for 5 seconds
Softening” will be flashing in top left corner
Set 1
st
cycle time in minutes BACKWASH
Set 2
nd
cycle time in minutes BRINE & SLOW
RINSE
Set 3
rd
cycle time in minutes BACKWASH 2
Set 4
th
cycle time in minutes FAST RINSE
Set 5
th
cycle time in kilos of salt required per regeneration
BRINE REFILL except WS2 which is in minutes

Related product manuals