WS1”, 1.5” & 2” Series Watersoftener
Installation Operation Maintenance Manual
SIMPWS1 REV3 13/07/11 PAGE 10 OF27
NEXT
NEXT
NEXT
NEXT
NEXT
NEXT
regeneration has been entered as 2 AM, this can be changed if
necessary.
6.3 Factory Programming
Regeneration Programming
(All programming below is Factory set)
To alter settings – Press “↑” and “↓” keys To back up at any stage – Press
“REGEN” To save any changes – Press “SET CLOCK”
Press and hold together for 5 seconds
“Softening” will be flashing in top left corner
Set 1
st
cycle time in minutes – BACKWASH
Set 2
nd
cycle time in minutes – BRINE & SLOW
RINSE
Set 3
rd
cycle time in minutes – BACKWASH 2
Set 4
th
cycle time in minutes – FAST RINSE
Set 5
th
cycle time in kilos of salt required per regeneration
– BRINE REFILL except WS2 which is in minutes