Planned Maintenance and Lubrication
6.9
Battery Charging
1. Please prevent the battery from water or inltration
on any liquid.
2. Do not let the battery close to any open ame, heat,
ammable and explosive objects.
3. Do not place the battery vertically on a conductive
object to prevent the electrodes from being touched
by protruding objects.
4. Charge the battery at an ambient temperature of 0
°C to 40 °C.
5. Insert the battery into the charging base.
6. The status LED (1) lights up.
Status LED
Battery is charging Red, Steady light
Battery fully charged Green, Steady light
Charger fault Yellow, ashing
Battery fault Yellow, Steady light
The battery is fully charged after 2.5 hrs of charging
at 100-240VAC.
The battery can be operated continuously for 3 hrs from a fully charged
state.