Lithium Power Supply User Manual
!
Page 25
!
!
!
7.7. 12VDC Output
Figure 21
In the 12VDC Output menu it is possible to get details about:
Current operation status
Current output power
Current output voltage
Current output current
Furthermore following settings are possible to set:
Jumpstart
Press “Arrow Up” and to activate.
If Jumpstart is enabled the unit will provide a 12VDC 50A output on the DC input for 5 minutes. The
purpose of this function is to charge the start battery of the vehicle.
Shutdown Delay
Shutdown delay for the 12VDC output. The 12VDC output This function leaves the 12VDC output enabled
for the set time, after the unit is shutdown.
Default inactive
Available range (00:01:00 10:00:00 or infinity). Press to exit.
For deactivating the function set the level below 00:01:00. The time will change to “inactive”. Press
to exit