EF-701M INTERFACE 5-1
SPECIFICATIONS
EF-701M TECHNICAL
SPECIFICATIONS
dBu is an absolute measurement. 0 dBu is referenced to
0.775 volts RMS
CLEAR-COM FORMAT
LINE CHARACTERISTICS
Max Level Before Clipping >=20dBu
Impedance: >=10K
Ω
SIGNALLING
Receive: <=4 VDC
Send: >=11VDC
RTS FORMAT
LINE CHARACTERISTICS
Max Level Before Clipping >=20dBu
Impedance: >=10K
Ω
SIGNALLING TONE
Send frequency: 20kHz
±1KHz
Receive frequency: 20kHz
±500Hz
Send level: >=-6dBu
Receive level: <=-20dBu
GENERAL CHARACTERISTICS
Frequency response:
Party Line - Matrix
200-10KHz ± 3dB
Matrix - Party Line
200-10KHz ± 3dB