INSTALLATION INSTRUCTIONS
Water drainage:
- During dehumidifying modes, remove the upper
drain plug from the back of the unit, install the drain
connector (5/8" universal female adaptor) with
3/4" hose (locally purchased). For the models
without a drain connector, just attach the drain
hose to the hole. Place the open end of the hose
directly over the drain area in your basement
floor. Please refer to Fig.20a.
NOTE: For the double-duct design, water drainage
is not needed during cooling operation. If performing
above water drainage during cooling operation, the
cooling efficiency/capacity will be reduced.
NOTE: Make sure the hose is secure so there are
no leaks. Direct the hose toward the drain, making
sure that there are no kinks that will stop the water
from flowing. Place the end of the hose into the drain
and make sure the end of the hose is pointed down to
let the water flow smoothly (see Fig.20a, 20b, 21a). Do
not ever point it up (see Fig.21b).
- When the water level of the bottom tray reaches
a predetermined level, the unit beeps 8 times,
the digital display area shows "P1".At this time
the air conditioning/dehumidification process will
immediately stop. However, the fan motor will
continue to operate(this is normal). Carefully move the
unit to a drain location, remove the bottom drain plug
and let the water drain away (Fig.22). Reinstall the
bottom drain plug and restart the machine until the
"P1" symbol disappears. If the error repeats, call for
service.
NOTE: Be sure to reinstall the bottom drain plug
before using the unit.