CI-154 User’s Manual
Page 7
1.5 Specifications
Illumination source:
Laser diode, 50 mW
Light Collection Optics:
Elliptical mirror
Detection:
Silicon photo diode
Size sensitivity:
0.30 m
Particle channel sizes:
Four sizes: 0.3, 0.5, 1.0, 5.0 m
Size resolution:
Meets requirements of ISO 21501-4 - 10% typical
Concentration limit:
1.0 x 10
6
particles per cubic foot (10% coincidence)
(35.3 x 10
6
particles per cubic meter)
Sample flow rate:
1.00 cubic feet per minute
(0.028 cubic meter or 28.3 liters per minute)
Flow rate control:
Electronic, automatic closed loop
Sample tube extension:
3/8” (9.525 mm) I.D., up to 20 ft. (6.1 meters) max. length
Max. False Count Rate:
7.1 per CM >0.3 µm (95% UCL) per ISO 21501-4
(1 count per five minutes)
Battery:
Replaceable 9.6 Volts, 12.6 Amp hour Nickel Metal Hydride
Battery operation time: 5.5 to 6.5 hours continuous operation
Time to charge battery:3.5 to 4.0 hours
Display:
TFT Color LCD, ¼ VGA touch screen
Printer:
Thermal Dot Matrix
Memory:
3,000 samples, date and time stamped
Unit ID:
User selectable
User ID:
Up to 20 users, besides supervisor, with password
Security:
Four security levels with user authentication
Location ID:
Up to 100 per program; 16 characters long.
Program:
Up to 30 user-defined and named, containing IDs and settings.
Input/Output (RS-232):
ASCII command set, CSV data output with check code
+5 VDC @ 400 mA provided on pin 9
Input/Output (Ethernet)
10/100Base-T, half or full duplex (auto sensing), http web
server, Ethernet Modbus
®
server and TELNET server
Input/Output (USB)
Transfer of stored data memory to jump drive
Transfer of user-defined programs to/from jump drive
Transfer of unit settings to/from unit via jump drive
Beep On Count:
0.3 m and greater.
Audible alarm:
Built-in
Alarm output:
Dry contacts, normally open or closed via alarm connector.
Connector also has +12VDC @ 250mA.
Alarm limits:
Programmable for all particle channels and flow.
Dimensions:
H-W-D: 8.65 x 8.5 x 9.5 inches (21.97 X 21.6 X 24.1 cm)
Weight:
11.0 lb (4.99 Kg) without battery
14.25 lb (6.46 Kg) with battery
Power:
Auto switching: 100240 VAC, 47/63 Hz, 90VA max
Fuses:
two 5 X 20 mm, 250V/2.0 Amp Slow
Operating range:
036º C, 1090% RH, non-condensing
Calibration:
Factory Prime Calibration complying with ISO 21501-4.
NIST traceable using CalPro 2.00 (or later) software program.
Calibration frequency:
Recommended every 12 months.
Gas compatibility:
Air, nitrogen; consult factory regarding other gases.