10 ELFOFresh² BT15B012GB-00
The Clivet solution
ELFOFresh² 70-120
A compact air renewal and purication unit for houses from 50 to 90 m
2
Thanks to the new automatic speed control in relation to the pressure drops of the system, the centrifugal fans, which are directly
coupled to a DC motor, ensure a constant air ow rate.
The benets deriving from this design solution are featured along the three development and management stages of the system, indeed:
▶
It simplies the design of the air distribution system, as it is not necessary to take into account extremely small tolerances when
calculating the pressure drops of the system itself.
▶
It makes it easier to install and activate the unit in the event of system congurations carried out during installation that dier from
the ones reported on the project.
▶
In the event of soiled lters or incorrect cleaning of the system, it prevents the machine from going in stand-by or from less than
optimal operation due to a drop in the ow rate.
A. Air intake lter
It puries external renewal air before it is introduced in rooms
with a standard lter (G3). It can be tted with an optional high
eciency electrostatic lter (H10).
B. “Standard” exhaust air lter
These units with reduced power are tted with the internal G2
lter as standard.
C. Supply fan
The new control allows to maintain a constant rotation speed as
the system’s pressure drops vary, with 60% less power absorbed
compared to traditional fans.
D. Compressor
R134a airtight rotary compressor chosen to optimise the reduced
power unit with higher performance levels.
E. Exhaust fan
The new control allows to maintain a constant rotation speed as
the system’s pressure drops vary, with 60% less power absorbed.
F. Electrical panel
Easy to access in order to conduct maintenance and take it out
through the openings.
G. White prepainted aluminium unit
H. DN150 air ducts
Air distribution system size designed in relation to the unit size.
I. Internal exchanger
Finned direct expansion exchanger with copper tubes and
aluminium ns
Reduced pressure drops compared to passive recovery units.
L. External exchanger
Finned direct expansion exchanger with copper tubes and
aluminium ns
Reduced pressure drops compared to passive recovery units.
Air renewal in relation to the surface of the house:
Model ELFOFresh² 70 ELFOFresh² 120
Room surface [m
2
] 40 50 60 70 80 80 90 100 110 120 140 150
Volume of a room with h=2,7m [m
3
] 108 135 162 189 216 216 243 270 297 324 378 405
Nominal air ow rate [m
3
/h] 70 70 70 70 70 120 120 120 120 120 120 120
Renewal rate [vol/h] 0,65 5,2 0,43 0,37 0,32 0,56 0,49 0,44 0,4 0,37 0,32 0,3