24 ELFOFresh² BT15B012GB-00
Electrical data
Size 70 120 200 300 500 650
F.L.A. - Full load current at max admissible conditions
F.L.A. - Compressor 1 A 0,87 1,62 2.20 3.10 5.13 6.80
F.L.A. - Single supply fan A 0,30 0,90 1.20 1.20 1.20 1.20
F.L.A. - Single exhaust air fan A 0,30 0,90 1.20 1.20 1.20 1.20
F.L.A. - Total A 1,47 3,42 5.60 6.50 8.53 10.2
L.R.A. - Locked rotor amperes
L.R.A. - Compressor 1 A 4,35 8,10 12.0 16.5 25.2 37.0
F.L.I. - Full load power input at max admissible conditions
F.L.I. - Compressor 1 kW 0,19 0,34 0.47 0.69 1.10 1.52
F.L.I. - Single External Fan kW 0,037 0,115 0.165 0.165 0.165 0.165
F.L.I. – Single exhaust air fan kW 0,037 0,115 0.165 0.165 0.165 0.165
F.L.I. - Total kW 0,264 0,57 1.03 1.25 1.66 2.08
M.I.C. Maximum inrush current
M.I.C. - Value A 4,95 9,9 14.4 18.9 23.4 39.4
power supply 230/1/50 Hz +/-10%
Electrical input of optional components
To obtain the electrical input of the unit including accessories, add the standard data in Electrical Data table to those for the selected accessories.
Size 70 120 200 300 500 650
F.L.A. - Full load current at max admissible conditions
F.L.A. EHPCX - Preheating electric heaters from 0.7 kW A 3,04 3,04 - - - -
F.L.A. EHPCX - Preheating electric heaters from 1.5 kW A - - 6,5 6,5 - -
F.L.A. EHPCX - Preheating electric heaters from 3 kW A - - - - 13 13
F.L.A. HSE3MX/HSE3LX - Electrode boiler steam humidier from 3 kg/h A - - 9,8 9,8 9,8 9,8
F.L.A. FES/FESX - Electronic lter A 0,1 0,1 0,1 0,1 0,1 0,1
F.L.A. CDP - Condensate discharge pump A 0,07 0,07 0,07 0,07 0,07 0,07
F.L.I. Power consumption
F.L.I. EHPCX - Preheating electric heaters from 0.7 kW kW 0,7 0,7 - - - -
F.L.I. EHPCX - Preheating electric heaters from 1.5 kW kW - - 1,5 1,5 - -
F.L.I. EHPCX - Preheating electric heaters from 3 kW kW - - - - 3 3
F.L.I. HSE3MX/HSE3LX - Electrode boiler steam humidier from 3 kg/h kW - - 2,25 2,25 2,25 2,25
F.L.I. FES/FESX - Electronic lter kW 0,025 0,025 0,025 0,025 0,025 0,025
F.L.I. CDP - Condensate discharge pump kW 0,016 0,016 0,016 0,016 0,016 0,016

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CLIVET ELFOFresh2 CPAN-U 70-120 Series and is the answer not in the manual?

CLIVET ELFOFresh2 CPAN-U 70-120 Series Specifications

General IconGeneral
BrandCLIVET
ModelELFOFresh2 CPAN-U 70-120 Series
CategoryAir Cleaner
LanguageEnglish

Related product manuals