BT15B012GB-00 ELFOFresh² 21
Filtration
Pleated lter, made up of a galvanized plate frame with galvanized and electric-welded protective mesh and 100% regenerable polyester ltering media
with PVC resin. G3 eciency according to CEN-EN 779 standard (Eurovent class EU3 - average eciency 84% ASHRAE 52 - 76 Atm). Self-extinguishing
(resistance to re class 1 - DIN 53438). (size 70-650)
Flat lter used for the return of fresh air and ambient air, consisting of a galvanized sheet metal frame with galvanized electrowelded protective meshes and
100% polyester renewable ltering septum with G2 eciency level in accordance with the CEN-EN 779 standard (size 70-120).
Together with the lter is provided the dierential pressure switch in order to signal its cleaning.
Electrical panel
Size 70-120:
Electrical panel located inside the unit and can be easily accessed from the bottom or sides via the removable panels.
Size 200-650:
The electrical panel assembled outside the unit is connected to it by a fast- connect cable (2 m) its remotization in positions where the maintenance/control
of the parameters is easier.
Size 70-650:
The capacity section includes:
compressor and fan fuses
fan control contactors
compressor control contactor
The control section is made up of a card with microprocessor control that allows the unit control according to the dierent air input conditions.
The control section includes:
Probe of the outdoor air temperature.
Probe to measure the temperature and supply air humidity of the room
Temperature probe of the air return from the ambient (thermostat)
Remote On-O
Thermostat
The HID-P1 local room control allows:
to control just one ELFOFresh² unit
Setting the desired temperature and humidity
ON/OFF
change Summer/Winter
Setting the ventilation-only mode
Diagnostics management with specic code according to the type of error
Dimensions: 184x82x27 mm
The thermostat is connected to the unit via a shielded twisted-pair cable at a maximum distance of 15m.
Outdoor air external bypass damper
Damper that draws air from the fresh air intake and brings it up to the exhaust coil. The damper, by means of an on-o actuator, is opened in summer
operating, with the compressor in operation and with exhaust fan at max. speed, so as to increase the air ow to the condensing coil: In this way, cooling
eciency is increased without creating negative pressure in the room.
Antivibration
Ceiling and oor spring antivibration mounts kit
The anti-vibration kit consists of 4 base spring vibration isolators, 4 M8 nuts, 4 M8 screws
Accessories separately supplied
CDPX: condensate discharge pump (size 70-650)
EHPCX: electric heaters 0,7 kW in duct (size 70-120)
electric heaters 1,5/3 kW in duct (size 200-650)
FESX: Electronic lter (size 70-650)
HSE3LX: Immersed electrode humidier DN200 (size 200-300)
HSE3MX: Immersed electrode humidier DN250 (size 500-650)
FAEX: Exhaust air lter (size 200-650)
CMMBX - Serial communication module to supervisor (MODBUS)
ELFOAir distribution
ELFOAir Option list at page 44

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CLIVET ELFOFresh2 CPAN-U 70-120 Series and is the answer not in the manual?

CLIVET ELFOFresh2 CPAN-U 70-120 Series Specifications

General IconGeneral
BrandCLIVET
ModelELFOFresh2 CPAN-U 70-120 Series
CategoryAir Cleaner
LanguageEnglish

Related product manuals