1.6.5 Evaporator Coil Temperature Protection
Off: Compressor stops.
Decrease: Decrease the running frequency to the lower
level per 20 seconds.
Hold: Keep the current frequency.
Resume: No limitation for frequency.
1.7 Auto Mode
This mode can be selected with the remote controller
and the temperature setting can be adjusted between
16°C~30°C.
In auto mode, the machine selects cooling, heating,
auto-drying or fan-only mode on the basis of T1,Ts, T4
and relative humidity.
1.8 Drying Mode
In drying mode, AC operates the same as auto fan in
cooling mode.
All protections are activated and operate the same as
they do that in cooling mode.
Low Room Temperature Protection
If the room temperature is lower than 10°C, the compressor
ceases operations and does not resume until room
temperature exceeds 12°C.
1.9 Forced Operation Function
Press the AUTO/COOL button, the AC will run as below
sequence:
Forced auto Forced cooling Off
Forced cooling mode:
The compressor and outdoor fan continue to run and
the indoor fan runs at breeze speed. After running for 30
minutes, the AC will switch to auto mode with a preset
temperature of 24°C(76°F).
Forced auto mode:
Forced auto mode operates the same as normal auto mode
with a preset temperature of 24°C(76°F).
The unit exits forced operation when it receives the
following signals:
Switch off
Changes in:
mode
fan speed
sleep mode
Follow me
1.10 Timer Function
The timing range is 24 hours.
Timer On. The machine turns on automatically at the
preset time.
Timer Off. The machine turns off automatically at the
preset time.
Timer On/Off. The machine turns on automatically at
the preset On Time, and then turns off automatically
at the preset Off Time.
Timer Off/On. The machine turns on automatically at
the preset Off Time and then turns off automatically at
the preset On Time.
The timer does not change the unit operation mode.
If the unit is off now, it does not start up immediately
after the “timer off” function is set. When the setting
time is reached, the timer LED switches off and the
unit running mode remains unchanged.
The timer uses relative time, not clock time
1.11 Sleep function
The sleep function is available in cooling, heating, or
auto mode.
The operational process for sleep mode is as follows:
When cooling, the temperature rises 1°C (to not
higher than 30°C/86°F) every hour. After 2 hours,
the temperature stops rising and the indoor fan is
fixed at low speed.
When heating, the temperature decreases 1°C(to