Specifications
Page 6
Outdoor coil
Number of rows 1 2.0 1.6
Tube pitch(a)x row pitch(b) mm 21x22 21x22 21x22
Fin spacing mm 1.3 1.3 1.3
Fin type (code) Hydrophilic aluminum Hydrophilic aluminum Hydrophilic aluminum
Tube outside dia.and type mm Φ7,Inner groove tube Φ7,Inner groove tube Φ7,Inner groove tube
Coil length x height x width mm 745*504*22 860*504*44 900*44*609
Number of circuits 2 4 5
Outdoor air flow m3/h 2200 2100 3500
Outdoor sound pressure level dB(A) 53.6 56 60
Outdoor sound power level dB(A) 62 65 68
Throttle type EXV EXV EXV+Throttle valve
Outdoor unit
Dimension(W*D*H) mm 765x303x555 805x330x554 890x342x673
Packing (W*D*H) mm 887x337x610 915x370x615 995x398x740
Net/Gross weight Kg 26.6/29 32.5/35.2 43.9/46.9
Refrigerant type
Type - R32 R32 R32
GWP - 675 675 675
Charged quantity Kg 0.72 1.15 1.5
Design pressure MPa 4.3/1.7 4.3/1.7 4.3/1.7
Refrigerant piping
Liquid side/ Gas side mm(inch) Φ6.35/Φ9.52(1/4"/3/8") Φ6.35/Φ12.7(1/4"/1/2") Φ9.52/Φ15.9(3/8"/5/8")
Max. refrigerant pipe length m 25 30 50
Max. difference in level m 10 20 25
Ambient temperature
Cooling °C -15~50 -15~50 -15~50
Heating °C -15~24 -15~24 -15~24
Qty’per 20’ /40’ /40’HQ Outdoor unit 132/264/352 114/234/312 99/198/198
Notes:
1) Capacities are based on the following conditions:
Cooling(T1): - Indoor Temperature 27°C(80.6°F) DB /19 °C(66.2°F) WB Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB
-Outdoor Temperature 35 °C(95°F) DB /24 °C(75.2°F) WB -Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB
-Interconnecting Piping Length 5m - Interconnecting Piping Length 5 m
- Level Difference of Zero. - Level Difference of Zero.
2) Capacities are Net Capacities.
3) Due to our policy of innovation some specifications may be changed without notification.