Specifications
Page 78
IA3-XY 70M + MC3-Y 70M
[SI_Unit]
INDOOR
AIRFLOW (CMH)
HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE
OUTDOOR
DB(°C)
TC:TOTAL CAPACITY IN KILOWATTS (KW) PI:TOTAL POWER IN KILOWATTS (KW)
Indoor Conditions (DB °C ) Indoor Conditions (DB °C )
16.0 20.0 22.0 24.0 16.0 20.0 22.0 24.0
992
-15.0 5.23 5.18 5.16 5.11 2.30 2.38 2.33 2.33
-10.0 5.59 5.53 5.51 5.45 2.45 2.54 2.48 2.49
-7.0 5.85 5.80 5.77 5.71 2.61 2.70 2.64 2.65
-5.6 6.00 5.94 5.91 5.85 2.53 2.55 2.55 2.56
-2.8 6.11 6.06 6.03 5.97 2.39 2.40 2.40 2.41
0.0 6.17 6.09 6.06 6.03 2.25 2.25 2.25 2.26
2.8 6.46 6.38 6.32 6.29 2.12 2.12 2.12 2.12
5.6 6.96 6.87 6.81 6.75 2.00 1.99 1.99 1.99
7.0 7.48 7.39 7.24 7.19 1.94 1.86 1.92 1.92
11.1 7.79 7.68 7.62 7.59 1.74 1.73 1.72 1.71
13.9 8.05 7.94 7.88 7.85 1.61 1.59 1.57 1.56
16.7 8.34 8.23 8.17 8.11 1.48 1.45
1.43 1.43
18.0 8.46 8.34 8.29 8.23 1.43 1.39 1.38 1.36
1118
-15.0 5.33 5.28 5.23 5.20 2.32 2.40 2.34 2.35
-10.0 5.69 5.63 5.58 5.55 2.47 2.56 2.50 2.51
-7.0 5.96 5.90 5.85 5.82 2.63 2.72 2.66 2.67
-5.6 6.11 6.06 6.00 5.97 2.55 2.57 2.58 2.59
-2.8 6.23 6.17 6.14 6.09 2.41 2.42 2.43 2.43
0.0 6.29 6.20 6.17 6.14 2.27 2.27 2.28 2.28
2.8 6.58 6.49 6.43 6.40 2.14 2.14 2.14 2.14
5.6 7.07 6.98 6.96 6.90 2.02 2.01 2.01 2.01
7.0 7.63 7.53 7.39 7.33 1.96 1.88 1.95 1.94
11.1 7.94 7.82 7.79 7.74 1.76 1.74 1.73 1.73
13.9 8.23 8.11 8.05 8.00 1.63 1.61 1.59 1.58
16.7 8.49 8.37 8.32 8.26 1.50 1.47 1.45 1.43
18.0 8.63 8.52 8.46 8.40 1.43 1.41 1.39 1.37
1247
-15.0 5.39 5.34 5.31
5.29 2.33 2.42 2.37 2.38
-10.0 5.75 5.70 5.67 5.64 2.49 2.58 2.53 2.54
-7.0 6.03 5.97 5.94 5.91 2.65 2.75 2.69 2.70
-5.6 6.17 6.11 6.09 6.06 2.58 2.59 2.60 2.61
-2.8 6.32 6.23 6.20 6.17 2.43 2.44 2.45 2.46
0.0 6.38 6.29 6.23 6.20 2.29 2.29 2.30 2.30
2.8 6.64 6.55 6.52 6.46 2.16 2.16 2.16 2.16
5.6 7.16 7.07 7.01 6.98 2.04 2.03 2.03 2.03
7.0 7.71 7.62 7.48 7.42 1.98 1.90 1.97 1.96
11.1 8.03 7.94 7.88 7.82 1.78 1.76 1.75 1.74
13.9 8.32 8.20 8.14 8.08 1.65 1.62 1.61 1.60
16.7 8.61 8.49 8.43 8.34 1.52 1.48 1.47 1.45
18.0 8.75 8.61 8.55 8.49 1.45 1.43 1.41 1.39
Note: The table shows the case where the operation frequency of a compressor is fixed.