7 - REGULATION
UNIT PARAMETER tab 3
264 DeltaMinNC Threshold of min. NC
265 MinFanCoolNC Fan NC min. press
266 MaxFanCoolNC Fan NC max press
267 CutOffCFNC Refrigerant circuit shutdown (compressor) in NC
268 OffsetNC Offset on the heat regulator step in FC
269 TimeBypNC Time of bypass of the CutOffCFNC threshold control
283 Address ModBus supervision serial address
284 Baud Rate Serial Baud Rate (0=4800 / 1=9600 2=19200) of supervision
285 Parity Parity 0=NO / 1=Odd 2=Even serial of supervision
287 AddressZB ModBus serial address of keypad service
288 BaudRateZB Baud Rate (0=4800 / 1=9600 2=19200) serial of keypad service
289 ParityZB Parity 0=NO / 1=Odd 2=Even serial of keypad service
290 TimeoutRete Modbus net Timeout
291 DeviceId ModBus XC3 serial address
292 BaudRateXC3 Baud Rate (0=1200 1=2400 2=4800 3=9600 4 =19200) XC3 serial
293 ParityXC3 Parity 0=NO / 1=Odd 2=Even XC3 serial
294 AdCorrente Reading 1 area
295 AdTensione Reading 2 area
296 AdFrequenza Reading 3 area
306 NumberMachine Number of connected units in Minirete
308 NumSleep Number of units in standby for rotation
309 ControlAlarm Enables exclusion of the unit in alarm
310 OffsetMS Offset between the SetPoint of the units
311 TimeOut Polling waiting time from master
312 TimeWork Wear updating time
313 TimeAlarm Alarm duration before the standby
314 TimerUnitMS Sturt-up delay of 1°capacity step of each unit in mininet
315 OffsetMSFNC Offset between the SetPoint of the units in Mininet with FNC= on
316 FNCSleepMode Enabling (only) FNC when the unit is in Sleep
317 ACSSleepMode Enabling (only) DHW when the unit is in Sleep
318 DelayDfr Wait for new defrosting enabling after the last defrosting performer by a unit in mininet
343 SetIniezione Supply temperature of the injection valve opening
344 IstIniezione Injection hysteresis
348 DeltaSetImp Hysteresis for signalling of satisfied heat regulator
357 SanitariaHeatMode Management for DHW forced production at system thermoregulation in heat satisfied 1=Yes/0=No
358 DelayValvS Time of DHW valve opening
359 CompExtH2OS Enabling comp. for Out. Temp. of the DHW 1=Yes0=No
360 MaxCompH2OS Max. Outdoor T correction value for DHW setpoint
361 PriorCoolH2OSan 0=DHW priority,1=System priority
362 PriorHeatH2Osan 0=DHW priority,1=System priority