MAINTENANCE
Daily or weekly
Clean rest room and toilet fixtures using only biodegradable cleaners (enzymes)
Add 1 cup of bulking agent to toilet after every solid use
MonThly
Inspect the ‘In-service’ chamber. Depending on usage, prepare an empty chamber for use once
the chamber becomes full (refer to Rotating the Chambers, page 18)
Check vent pipe and remove any foreign matter
Check the fan is operating
Check that the system is draining correctly
Remove and clean the fan and fan mesh. Ensure the fan is free of dust and moving easily
TiPs
Carry a spare fan
Periodically check your drain hose (aka excess liquids hose) for blockages. Wear protective
clothing and gloves. To check if there is any blockage around the drain outlet under the
perforated false floor, disconnect the drain hose from the chamber and pour hot water in the
chamber. To check if there is any blockage in the drain hose, pour hot water down the hose.
It is important to observe safety procedures when dealing with fresh human waste.
Please ensure you wear protective clothing (gloves and old clothes).
Do not attempt to move the chambers on your own.