23
7.4 Temperament
z You can change the temperament other than the defult equal one.
z Operation:【SHIFT】ÖA1
【Temperament】Ö【Set value】Ö【ENTER】
z Default value:000
z Value range:000-012
z Please refer to the appendix <Temperament list> for more information.
The Scale and Temperament functions can not be used at the same time.
When the temperament function is enabled, the keyboard will be in the mono
mode.
7.5 DRAWBAR
z While playing a organ voice, you can use the DRAWBAR function to make the 9
faders work as the organ drawbars (data value will be sent reversely), so you can
control the organ voice conveniently.
z Operation:【SHIFT】ÖF#1【Drawbar】Ö【Set value】Ö【ENTER】
z Default value:
Off
z Value range:Off、On
7.6 TEMPO
z By using the TEMPO function, you can send the TEMPO change data to control the
TEMPO of the external sequencer.
z Operation:【SHIFT】ÖG1
【Tem po 】Ö【Set value】Ö【ENTER】
z Default value:Off
z Value range:Off, 30-250
If the external sequencer does not accept the Tempo change data, or it is not
properly configured, the TEMPO function will not work.
7.7 MIDI RESET message
z You can reset the external MIDI device by sending a MIDI reset message.
Name Key MIDI message sent
Reset All Control D3 CC#121
GM On D#3 F0 7E 7F 09 01 F7
GM2 On E3 F0 7E 7F 09 03 F7
GS On F3 F0 41 10 42 12 40 00 7F 00 41 F7
XG On F#3 F0 43 10 4C 00 00 7E 00 F7
CME On G3 F0 00 20 63 00 00 00 00 7F F7
Please make sure your MIDI device support the related MIDI reset message
before using this function.