Troubleshooting guide
36 Chapter 3: Service & maintenance 98-137261-F
Self Test
Tap Self Test to start the self test of the SAILOR 6004 Control Panel. For further
details on the self test see the installation manual of the SAILOR 6004 Control
Panel.
About
Tap About to view the following:
• Legal with legal and copyright information, open source licences, etc.
• Version with software versions and serial number of the SAILOR 6004
Control Panel.
• Network with IP address and MAC address of the SAILOR 6004 Control
Panel.
Troubleshooting guide
Problem Symptom Remedy
The
SAILOR 6390
Navtex Receiver
will not turn on.
Green power LED
on SAILOR 6390
Navtex Receiver
is off.
If the power cable is connected directly to the
SAILOR 6390 Navtex Receiver then check that
ON IN is wired to VBAT-.
No message
can be received.
Test LED flashes. Check the antenna installation.
The Time
column shows
dashes, but not
time
No valid message
time.
Check the GNSS connection.
No connection
to the Navtex
Receiver
The display
shows:
Caution:
connection lost
to BDU
1. Check the cable between the Navtex receiver
and the Control Panel.
2. Someone has not logged out properly of the
Service Interface.