Specification
DataMan 282
Storage
Temperature
-10–60 °C (14–140 °F)
Humidity <95% non-condensing
Environmental
IP67
Note: IP67 rating applies only if all blind plugs and cables are attached properly, or the
provided connector plug is installed. Also make sure that the IP67-rated cover is
installed properly.
Shock
IEC 60068-2-27 - 500 shocks in each polarity of each (X, Y, and Z) axis, 3000 shocks total,
semi-sinusoidal, 11 g, 10 ms
Shock (Shipping
and Storage)
ISTA-1A Standardized Testing - Packaged Products 150 lb or less
Vibration IEC 60068-2-6: vibration test in each of the three main axis for 2 hours @ 10 Gs (10 to 500 Hz at
100m/s
2
/ 15 mm)
Vibration
(Shipping and
Storage)
FedEx Vibration Testing for packaged products 150 lbs or less
Codes
1-D barcodes: Codabar, Code 39, Code 128, Code 93, Code 25, Interleaved 2 of 5, Postal
Codes, UPC/EAN/JAN, MSI
2-D barcodes: Data Matrix (IDMax and IDQuick: ECC 0, 50, 80, 100, 140, and 200), QR Code,
microQR, PDF 417, AztecCode, DotCode, MaxiCode
42