R1000H
Alarmlist
Version: 2
Page: 7
Date: 07.11.2022
40
Max. purge time exceeded
If purge limit within the given max. purge time this error occur.
Check if liquid CO
2
is available. Check if liquid CO2 filter is blocked,
clean or replace if necessary. If this error happen frequently it could
indicate that the liquid supply line is not properly insulated and/or
that a degassing valve is required to achieve proper CO
2
supply.
41
Injection pressure exceeded
If chamber pressure increases to 10 bar this error occur.
Check if pressure transmitter =G01-TP1 is functioning correctly.
If chamber pressure read on the gauge =G01-PP1 is in fact too high
during injection inspect that the degassing is not blocked and that
degassing filters are intact. If all is ok, then the injection flow should
be decreased opening on valve =G01-Q1.
42
Temperature too high
This error is related to linear transduser that has a build in limit for
max. temperature. Inspect if temperature is actually too high or
replace linear transduser if no other fault state can be detected.
43
No magnet detected
This error is related to linear transduser not detecting a magnet for
linear position in the hydraulic cylinder. Inspect if the magnet has
come loose and replace it or linear transduser if necessary.