The function is called by pressing the O key. Then the Collamat
®
6600 gives the
following message:
>o
Potentiometer parameters.
S : Speed 03 30 m/min
P : Predispensing 000 100 mm
O : Position 000 100 mm
R : Reset to factory settings
SPACE : Exit
Select function with the Keys S,P,O,R,SPACE
The potentiometers can be selected with the S, P and O keys respectively. The R key
resets all values back to the factory settings.
For example the SPEED potentiometer will be programmed to a lower speed of
10 m/min and an upper speed of 20 m/min.
>s
SPEED (m/min)
U : Upper limit
L : Lower limit
ENTER : Keep
SPACE : Exit
Select limit with the keys U,L,ENTER, SPACE
With the U key the upper value is selected. L selects the lower value.
>u
Alter value: + or -, Keep: ENTER, SPACE: Exit
SPEED Upper limit : 20
Using the + and - keys the value may be increased or decreased. When the desired va-
lue is displayed, the dataentry may be finished with the ENTER key.
U : Upper limit
L : Lower limit
ENTER : Keep
SPACE : Exit
Select limit with the keys U,L,ENTER, SPACE
>
The lower value will be selected with the L key and adjusted with the + or - keys. When
both values match the desired range the dataentry will be finished with the ENTER key.