26
WEEKLY MAINTENANCE
3. CHECKING THE WHEEL BRAKE
Every week, check the distance between the work brake pads and the wheels. If necessary, adjust them
by means of the nuts, so they are at a distance of 3mm when homed.
ATTENTION: this operation must be carried out using gloves to protect
your hands.
4. CLEANING THE SOLUTION FILTER
1. Turn off the tap beneath the symbol (1)
2. Loosen the cap (2) of the solution filter
3. Remove the filter and rinse with a jet of water
4. Reassemble the filter and tighten the cap
5. Turn on the tap beneath the symbol (1)
WARNING: you are advised to always wear protective gloves in order to avoid
the risk of serious injury to your hands
5. CLEANING THE SOLUTION TANK
6. Loosen the front cap of the solution tank
7. Loosen the wing nut of the drainage cap (1) to the left of the tank, and remove the cap
8. Rinse the inside of the tank with a jet of water
9. Insert the cap in the tank, and retighten the wing nut (1)
WARNING: you are advised to always wear protective gloves in order to avoid
the risk of serious injury to your hands
2
1
1