4. Design and functioning
23
Automatic operation
If the mains pressure achieves the preset maximum
value, then the electric motor (-3-) will have its
speed lowered in order to allow for the delivery
amount to adapt to the actual need for compressed
air.
If the motor has reached minimum speed and the
load-system pressure continues to rise, solenoid
valve (-25-(Y4)) is deenergized (opened) and
solenoid valve (-26-(Y11)) continues energized
(open). Reservoir pressure is reduced to approx. 4 to
4.5 bar and the pressure-maintenance valve (-7-)
closes.
This way, no more compressed air will be supplied
to the mains.
If the mains pressure does not drop to the target
value within the programmed follow-up time, then
the system will shut down.
If the target value is achieved before the expiration
of the programmed motor follow-up time, then the
magnet valve will again be energized (-25-(Y4)).
The system will then go into load runs.