MNC-0500-026 9 of 32 Revision G
Amplifier Communication and Protocol, Rabbit CPU
Table 1-4 Command Reject Codes
ASCII
Character
Reject Reason
a Command byte not recognized
b Illegal parameter or parameter out of range
c System in local mode
d Slow command being executed
e Hardware or Software failure
f High voltage is OFF
g RF is inhibited
h HPA Power is OFF
i Invalid key or key sequence
j Change in setting can only be made locally
k A fault condition exists
l System in Automatic Mode
m-z Reserved
Table 1-5 ASCII Code Cross Reference
CHAR DEC HEX CHAR DEC HEX CHAR DEC HEX
NUL 000 00 + 043 2B V 086 56
SOH 001 01 , 044 2C W 087 57
STX 002 02 - 045 2D X 088 58
ETX 003 03 . 046 2E Y 089 59
EOT 004 04 / 047 2F Z 090 5A
ENQ 005 05 0 048 30 [ 91 5B
ACK 006 06 1 049 31 \ 092 5C
BEL 007 07 2 050 32 ] 093 5D
BS 008 08 3 051 33 ^ 094 5E
HT 009 09 4 052 34 095 5F
LF 010 0A 5 053 35 ‘ 096 60
VT 011 0B 6 054 36 a 097 61
FF 012 0C 7 055 37 b 098 62
CR 013 0D 8 056 38 c 099 63
SO 014 0E 9 057 39 d 100 64
EAR EXPORT CONTROLLED: The information contained in this Manual refers or relates to a product that is subject
to the U.S. Export Administration Regulations (EAR). Transfer of data herein by any means to a Foreign Person,
whether in the U.S. or abroad, may require an export license from the U.S. Department of Commerce.